TECHNICAL DITAILS
FEED WATER TDS 2000 ppm
Fluorides 1 PPM
Iron 0.1 PPM
Turbidity 5
pH 6.5 - 7.5
The plant has been designed as per the above parameters depending upon your water test report.
DESCRIPTION
PROCESS:
Raw
Water Pump? Sand Filter ? Carbon Filter ? Anti Scalent Dosing System ? Micro
Filtration? High Pressure Pump ? Membrane
FEED
WATER TDS 2000 PPM
PRODUCT
WATER 1000 Liter Per Hours
RECOVERY 65% to 75%
REJECTION 95%
In
case of high Turbidity customer needs to provide a settlement tank and Alum
dosing system is to be incorporated. The cost of the same has not been
considered with in the scheme.
Technical Specification:
Raw
Water Tank (Client Scope)
This
tank ensures a constant supply of the raw water to the machine.
Feed
Water Pump
The
system would require an Inlet Pressure of 2 Kg/cm2 minimum for smooth
operation. To provide the same the Raw Water Pump is being incorporated in the
system.
Description
Make
: Kirlosker
Power : 1.5 HP
230 Volts
Phase
: Single
Type
: Mono Block
PRESSURE
SAND FILTER
The
system is required to be feed with “0” turbidity water. The Pressure Sand
Filter is incorporated in the system to ensure the same. The Pressure Sand
Filter offers a filtration up to 30 microns.
The
Filter consists of a Non Corrosive Vessel that can withstand pressure up to 6.5
Kgs/cm2, Multi Graded Sand Filtration Media for filtration, Internal
Distribution System to distribute the water evenly inside the vessel for proper
filtration, Multi Port Value (MPV) for easier operation along with Back Wash
and Rinse facilities, a stand to hold the MPV in position and Pressure Gauges
to know the position of the sand filter.
The
filter is designed for 14m/sec internal flow for proper filtration.
Description:
Vessel Make : Pentair/eqv.
Size
: 13”54”
Media
: Silica Sand Multi Grade
Min
Operating Pressure : 1.5kg/Cm2
Max
Operating Pressure : 4.5kg/Cm2
Avg
Operating Pressure : 2-3kg/Cm2
ACTIVATED CARBON FILTER (ACF)
This
system is required to be feed with NIL Chlorine water. The Activated Carbon
Filter is incorporated in the system to ensure the same. It also ensures that
the water is color less, odor less and contains no dissolved gases.
The
Filter consists of a Non Corrosive Vessel that can withstand pressure up to
6.5 Kgs/cm2, Multi Graded Sand and Activated Carbon Filtration Media for
filtration, Internal Distribution System to distribute the water evenly inside
the vessel for proper filtration, Multi Port Value (MPV) for easier operation
along with Back Wash and Rinse facilities, a stand to hold the MPV in position
and Pressure Gauges to know the position of the Activated Carbon filter.
The
filter is designed for 14 m/sec internal flow for proper filtration.
Description:
Vessel
:
Size
: 13”54”
Media
: Activated Carbon
Min
Operating Pressure : 1.5kg/Cm2
Max
Operating Pressure : 4.5kg/Cm2
Avg.
Operating Pressure : 2-3kg/Cm2
ANTI
SCALENT DOSING SYSTEM
The
ANTI SCALENT DOSING SYSTEM gives the system an extra protection towards any
kind of scale formation over the membranes. Chemicals are chosen depending on
the water analysis report of the raw water. These chemicals are dosed in the
water inflow drop by drop. The chemicals agitate the dissolved particles in the
water so as not to allow them to settle down on the membrane surface.
Description:
Make
: E-Dose
Type
: Diaphragm Type Metering Pump
MOC
Of Diaphragm : PP
Capacity
: 6 LPH
Dosing Tank : 100 Ltr. HDPE
Dosing
Chemical : 1Ltr..(During Installation)
MICRON
FILTER
Due
to the induction of the Dosing Chemical some of the particles may coagulate in
the water. This coagulated particals cannot be allowed to enter the membrane.
The Micron Filter ensures that all such particles above the size of 5 Micron
are being filtered out of the water so as to enhance the system life. It also
ensures that even all undissolved particles above the size of 5 Micron are being
filtered out.
Description:
No.
Offered : Two
Jumbo
Housing : PP
Specs
: Single Elements
Filters
Nos. Offered : Two
Micron
Rating : 5 Micron
HIGH
PRESSURE PUMP
In
the system, the membrane filtration takes place at high pressure only in the
range of 8-14 KG/CM2. To provide such high pressure the Pressure Booster Pump
is being induced in the system to boost the pressure to the required level for
the proper filtration process.
Description:
Make
: Kirloskar, LUBI, CRI
Power
: Single Phase
Wattage
: 3-23
Type
: Vertical Multi Stage
Pressure
Rating : 1.5 M3 At 140m Head
Max
Pressure : 17 Kgs/Cm2
Normal
Operating Pressure : 8-14 Kgs/Cm2
DOSING
PUMP : E-DOSE
MEMBRANE
HOUSING
The
membrane housing provides the shell for the membranes to allow the highly
pressurized water to pass through the membrane.
Description:
MOC
: FRP
No.
Offered : TWO
Specs
: 440 (Two Element)
Max
Pressure : 21 Kgs/Cm2
Operating
Pressure : 9-14 Kgs/Cm2
MEMBRANE
The
system consists of Thin Film Composite Membrane made out of Poly Urethane
acetate that provides a filtration level upto 0.0001 micron. These operate at a
pressure between 9-14 KGS/CM2 this result in a dissolved salt rejection of upto
95%. The membrane separates the water into two streams. One is the premed or
the product water and the other is the rejection.
Description:
Make
: Vontron / Hydronautices/ CSM
Specs
: 4040
No.
Offered : Four
Operating
Pressure : 9-14 Kgs/Cm2
ACCESSORIES
ELECTRICAL
CONTROL PANEL
MOC
: Plastic
Power
: Single Phase
Conductivity
Meter : Inbuilt
LPS
Adjuster : Inbuilt
HPS
Adjuster : Inbuilt
WET
PANEL
MOC
: Stainless Steel
Flow
Meters : Two
Pressure
Gauges : Two
LPS
: One
HPS
: One
SKID
MOC
: Stainless Steel
PIPING
Raw
Water Pump to Micron Filter : UPVC
Micron
Filter to Flow Meters : UPVC
Product
Line : UPVC (As Per FDA & NSF)
Reject
Line : UPVC