TECHNICAL DETAILS:- RO 250 LPH
FEED WATER TDS 1000 PPM
Fluorides < 1 PPM
Iron < 0.1 PPM
Turbidity < 5
pH < 6.5 - 7.5
Outlet Water TDS - 100 PPM
In case of high Turbidity customer needs to provide a settlement
tank and Alum dosing system is to be incorporated. The cost of the same has not
been considered with in the scheme.
TECHNICAL SPECIFICATION
Description
PRESSURE SAND FILTER
The system is required to be feed with “0” turbidity water. The
Pressure Sand Filter is incorporated in the system to ensure the same. The
Pressure Sand Filter offers a filtration up to 30 microns.
The Filter consists of a Non Corrosive Vessel that can withstand
pressure up to 6.5 Kgs/cm2, Multi Graded Sand Filtration Media for filtration,
Internal Distribution System to distribute the water evenly inside the vessel
for proper filtration, Multi Port Value (MPV) for easier operation along with
Back Wash and Rinse facilities, a stand to hold the MPV in position and
Pressure Gauges to know the position of the sand filter.
The filter is designed for 14m/sec internal flow for proper
filtration.
ACTIVATED CARBON FILTER (ACF)
This system is required to be feed with NIL Chlorine water. The
Activated Carbon Filter is incorporated in the system to ensure the same. It
also ensures that the water is color less, odor less and contains no dissolved
gases.
The Filter consists of a Non Corrosive Vessel that can withstand
pressure up to 6.5Kgs/cm2, Multi Graded Sand and Activated Carbon Filtration
Media for filtration, Internal Distribution System to distribute the water
evenly inside the vessel for proper filtration, Multi Port Value (MPV) for
easier operation along with Back Wash and Rinse facilities, a stand to hold the
MPV in position and Pressure Gauges to know the position of the Activated
Carbon filter.
The filter is designed for 14 m/sec internal flow for proper
filtration.
Description:
ANTI SCALENT DOSING SYSTEM
The ANTI SCALENT DOSING SYSTEM gives the system an extra
protection towards any kind of scale formation over the membranes. Chemicals
are chosen depending on the water analysis report of the raw water. These
chemicals are dosed in the water inflow drop by drop. The chemicals agitate the
dissolved particles in the water so as not to allow them to settle down on the
membrane surface.
Description:
Description:
HIGH PRESSURE PUMP
In the system, the membrane filtration takes place at high
pressure only in the range of 8-14 KG/CM2. To provide such high pressure the
Pressure Booster Pump is being induced in the system to boost the pressure to
the required level for the proper filtration process.
ACCESSORIES
WET PANEL
PIPING