RO 5000 LPH TECHNICAL SPECIFICATIONS
Flow Rate :
Feed Water : 9000 Liter Per Hour
Treated Water : 6000 Liter Per Hour
Reject Water : 3000 Liter Per Hour
| 1 | RAW WATER PUMP | ||
| Purpose | To feed the Dual Media Filter at pressure more than 2.0 bar, which is min. operating pressure for filter. | ||
| Specifications | a) MOC : CI | ||
| b) Type : Horizontal Centrifugal | |||
| c) Flow Rate : 14400 liters per hour | |||
| d) Head : 25 m | |||
| e) Power Required: 3 HP | |||
| f) Electrical : 440 V, Three phase , 50 hz | |||
| g) Cycle : 2900 rpm | |||
| h) Make : Kirlosker, CRI, Crompton Greaves. | |||
| i) Quantity : 1 No. | |||
| 2 | DUAL MEDIA FILTER | ||
| Purpose | To remove the total suspended solids, dirt , iron and reduce silt density index which can foul the membranes | ||
| Specifications | Vessel : | ||
| a) Make : Pentier Or Equivalent b) Material of Construction : FRP c) Diameter : 30” | |||
| d) Height : 72” mm | |||
| e) Testing Pressure : 10 kg/cm2 | |||
| f) Opening : Top and Bottom | |||
| g) Quantity : 1 No. | |||
| Valve : | |||
| a) Make : Initiative | |||
| b) Material of Construction : | |||
| c) Type : Multiport Single lever value | |||
| d) Size : 1.5” inches | |||
| e) Maximum Flow Rate: 24000 LPH | |||
| f) Working Pressure : 2-4 Bar | |||
| g) Working : Down-Flow | |||
| Media : | |||
| Mixed bed sand media consisting of the following | |||
| i) Gravel ii) Pebbles iii) Quartz Sand iv) Anthracite | |||
| Average Porosity 50 micron particulate size | |||
| Bed depth : 600 mm | |||
| Pipelines & Accessories: | |||
| Pipe of PVC 10 Bar tested pressure | |||
| 3 | ACTIVATED CARBON FILTER | ||
| Purpose | To remove the total color, smell, odor, from the water. | ||
| Specifications | Vessel: | ||
| a) Make: Penteir Or Equilent b) Material of Construction: FRP c) Diameter: 30” | |||
| d) Height: 72” mm | |||
| e) Testing Pressure: 10 kg/cm2 | |||
| f) Opening: Top & Bottom | |||
| g) Quantity: 1 No. | |||
| Valve: | |||
| a) Make: Initiative | |||
| b) Material of Construction: Noryl | |||
| c) Type: Multiport Single lever value | |||
| d) Size: 1.5 inches | |||
| e) Maximum Flow Rate: 24000 LPH | |||
| f) Working Pressure: 2-4 Bar | |||
| g) Working: Down-Flow | |||
| Media: | |||
| Mixed bed sand media consisting of the following | |||
| i) Gravel ii) Pebbles iii) Carbon | |||
| Average Porosity 50 micron particulate size | |||
| Bed depth: 600 mm | |||
| Pipelines & Accessories: | |||
| Pipe of PVC 10 Bar tested pressure | |||
| 4 | DOSING SYSTEM | ||
| Purpose | To dose Antiscalant chemical to protect the scaling formation on RO membranes. | ||
| Specifications | a) MOC : PP ( E-dose) | ||
| b) Capacity : 6 LPH | |||
| c) Pressure : 7 Bar | |||
| d) Qty. : 1 No. | |||
| 5 | MICRON FILTER | ||
| Purpose | To remove the fine particles up to 05 microns and reduce silt density index levels to acceptable level. | ||
| Specifications | Cartridge Filter & Housing | ||
| Housing : | |||
| a) Make: Flowtec | |||
| b) MOC of Housing: PP | |||
| c) Length : 20” | |||
| d) Diameter: 5.5” | |||
| e) Quantity : 4 no. | |||
| Cartridge : | |||
| f) Make : Flowtec | |||
| g) Cartridge MOC : Polypropylene | |||
| h) Length: 20” | |||
| i) Diameter : 4.0” | |||
| j) Quantity: 4 no. | |||
| k) Micron rating : 05 micron | |||
| 6 | HIGH PRESSURE PUMP | ||
| Purpose | To feed the Reverse Osmosis Membrane at pressure more than the osmotic pressure taking into consideration flux rate, flow and recovery. | ||
| Specifications | a) MOC : Stainless Steel | ||
| b) Type : Vertical Multistage | |||
| c) Flow Rate : 10500 liters per hour | |||
| d) Head : 120 mwc | |||
| e) Power Required : 5 HP | |||
| f) Electrical : 440 V, three phase , 50 hz | |||
| g) Cycle : 2900 rpm | |||
| h) Make CRI or Lubi | |||
| 7 | RO MEMBRANE | ||
| Purpose | To remove the major part of TDS upto 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow and recovery. | ||
| Specifications | a) Type : Spiral Wounded | ||
| b) Diameter of Membrane : 8.0 inch | |||
| c) Length of Membranes : 1 Mt. | |||
| d) No. of Membranes : 5 | |||
| e) Recovery per Membrane : 10-15% | |||
| f) Salt Rejection per Membrane : 98-99% | |||
| g) Make of Membranes : Toray or Equilent | |||
| h) System Recovery : 45 -55 % | |||
| 8 | RO PRESSURE TUBE | ||
| Purpose | To pack Reverse Osmosis Membranes and operate at high pressure up to 300 psi | ||
| Specifications | a) MOC : FRP Composite | ||
| b) Diameter of Pressure Vessel : 8.2 inch | |||
| c) Length of Pressure Vessel : 120” | |||
| d) No. Pressure Vessels : 2 | |||
| e) No. of Membrane per Vessel : 2 and 3 | |||
| f) Make : Seaflo, Shark or Equilent | |||
| g) Position : Horizontal, Series | |||
| h) Arrays : 2 No. | |||
| 9 | ELECTRICAL PANEL | ||
| Purpose | A control panel is provided as a safety measure for the pumps & other electrical items. | ||
| Specifications | a) Complete Starters, Overload relays, and single-phase preventor for Pump. | ||
| b) Voltmeter, Ammeter, MCB’s, indicating lights | |||
| c) Push Buttons | |||
| 10 | INSTRUMENTATION | ||
| Purpose | a) Flow Meter : To measure the online flow of water | ||
| b) Low Pressure Switch : To protect RO pump from dry running | |||
| c) High Pressure Switch : To protect RO pump from back pressure | |||
| d) Pressure Gauges : For calculate ^P for each unit in RO system | |||
| Specifications | Rota Meter : | ||
| Quantity : 2 Nos.( permeate & reject line) | |||
| Range : 1.0 cu.m. per hour | |||
| Make : Flowtec | |||
| Pressure Switch : | |||
| Quantity : 2 No.(Low & High) | |||
| Range : 0-450 psi | |||
| Make : Indfos, India | |||
| Pressure Gauges : | |||
| Quantity : 6 No. | |||
| Range : 0 – 7 bar | |||
| Dail Size : 6 inches | |||
| Type : Bourdon | |||
| Make : H-Guru | |||
| 11 | PLUMBING & FITTINGS | ||
| a) Valves, pipelines RO module is in upvc, | |||
| c) The System will be on common SS base frame | |||